Micro-Processor Based Digital DC Drives from AutomationDirect

October 3, 2019

The IronHorse GSD8 series of DC drives is a microprocessor-based design with non-volatile memory storage that is programmable with adjustable parameters, programmable alarm outputs and offers a digital closed-loop algorithm for motor control. GSD8 output power available is 1/2 to 1hp at 120 VAC input and 1 to 2hp at 240 VAC input; output voltage is 90 VDC (120 VAC) and 180 VDC (240 VAC). Maximum current ratings are 5A and 10A.

GSD8 series DC drives are capable of factory or field configurations for a variety of industrial applications. GSD8 DC drives make use of either a pulse accumulation algorithm or a velocity PID algorithm that can be easily configured for operation as a speed controller, time-based process controller, or follower drive in a master-follower application. GSD8 drives are an ideal match for applications that require specialized I/O.

All units include a large 4-digit LED display; standard 1/8 or 1/4 DIN panel mount versions are available. The GSD8 universal power supply accepts 85-265 VAC at 50-60 Hz without switches or jumpers and a self-contained 5V power supply is provided for external sensor power.

IronHorse GSD8 Series DC drives from AutomationDirect start at $405.00 and are backed by a one-year warranty.

Learn more by visiting: www.automationdirect.com/dc-drives.

Related Articles



Editor’s Pick: Featured Article

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s scalable engineering software, u-control 2000, adapts individually to your requirements. And, the u-control is powerful, compact and fully compatible with Weidmüller’s I/O system u-remote. This article looks at what makes u-control the heart of your automation.

Programmable logic controllers (PLCs) are one of the main components of any automated system. A typical control system has inputs, outputs, controllers (i.e., PLCs), and some type of human interaction with the system, a human machine interface (HMI), for example.

Read More



Latest Articles

  • Why Use Low-Consumption Contactors in Your Motor Control Systems?

    April 15, 2025 By Tiffany Moore Organizations are under more pressure than ever to improve sustainability metrics. How can you help them succeed — and win more business in the process?    Building motor control systems with more sustainable parts is one piece of the puzzle. Control panel builders, system integrators, and design firms have an… Read More…

  • The Long Cable Run Dilemma: Where Should You Install the VFD?

    April 15, 2025 By Damien Herwegh Sophia, a dedicated electrical engineer in a large industrial complex, has been tasked with installing a drive system where the motor is located hundreds of meters away from the control room. Like many engineers before her, she considers the usual question: Should I place the drive in the electrical… Read More…