Drives and Control Solutions

April 30, 2019

By Linda Caron, Parker Hannafin

Safe Distance in Machine Design When machine safeguarding is used one of the most relevant (and least discussed) effective measures is safe placement of the equipment in relation to the hazard. This is especially true when trying to comply with the requirements to eliminate trapped energy under ISO 13849-1 where exhaust time and volume of compressed air in the machine play a role in creating a safe condition. Considerations must include those questions posed in a risk assessment such as severity of injury, frequency of exposure and so we begin to look at all aspects of the machine design.

DCS-Parker-2.jpg

International Standard ISO 13855 “Safety of Machinery - Positioning of safeguards with respect to 

the approach speeds of parts of the human body.”; defines these standards. Most commonly considered is how quickly can we bring the machine to a safe state? And, how far do we place the safety equipment to the hazard? We must not forget to include the switching time for machine safety devices and exhaust rates in faulted conditions. Exhaust flow is not mentioned but ultimately is a critical part of bringing a pneumatic machine to a safe state.

The time taken to ensure the safe condition of the machine is met is a combination of products, switching time and flow rates. These calculations cannot be done until you have identified which safety products you will utilize because they all have different flow rates and exhaust times. Faulted flow rates are flow rates in the worst-case scenario and are important considerations in calculating safe distances. You really want to know your exhaust time in choosing components because ultimately these times will impact where you place your machine guards.

 

Now, Let’s Consider T (time interval)

DCS-Parker-4.jpgStandards do not exist to explain the correlation of exhausting and spacing leaving the engineering community to use a common- sense approach on how to integrate safety exhaust valves.

The closest the standards come is to say the “overall system stopping time”. For safety this time interval would ideally include time to exhaust however, this is not always practical. Most suppliers of pneumatic safety exhaust valves will provide their data for varying machine volumes (as follows).

Note – a machine with 150L of trapped air at 6 bar needs 7.30 seconds to exhaust in faulted condition so it may not be practical to assume full exhaust of a large machine but rather how to responsibly ensure safety and utilize this data to make the best decision for your application.

Size for Both Switching Time and Exhaust Time Where Possible

Of critical consideration before selecting equipment is its switching time and exhaust time. I would say it is good engineering practice to include the switching time and the exhaust time of such a component in the safe distance calculations when possible. Ideally, hazardous locations would be designed to utilize a small area of compressed air for rapid depressurization but this isn’t always possible for the existing situation in the case of retrofitting a machine.

Including exhaust time is not always possible given the large size of some machines which may take several seconds to exhaust. Here, sound judgement and good engineering principles come into play. Once open to exhaust, the safety valve will begin to reduce the pressure build up in the machine rapidly bringing the machine finally to a safe state. If you are unable to space by exhaust time practically, there are some additional things you can do to enhance the safety such as safe stopping devices like rod locks or clamps.

Concluding Safe Distance with Exhausting Products

Safety exhaust valves serve three primary functions. The first is rapid exhaust of compressed air. The second function is to prevent a restart if a fault is detected. The third in the case of redundant designs is to ensure both channels are operational or to fail safe / exhausted (even if no power is available).

Consider Faulted Exhaust Time

Chose the safety exhaust valve with the quickest faulted exhaust time to depressurize the machine as quickly as possible. If your machine has a volume of 5.30 ft3 (150 L) operating at 90 psig or 6 bar. The Parker P33 will exhaust in faulted condition (worst case) in 7.30 seconds. Use the manufacturer’s faulted exhaust time data to understand your situation fully.

Utilize secondary means

When the machine takes time to exhaust and an unsafe condition is still present utilize secondary means of stopping, blocking or holding a load in place such as clamping and rod locks.

Double up

If your pneumatic air supply offers enough pressure to meet the minimum operation pressure requirements of the safety exhaust valve, consider using two safety exhaust valves (as shown to the right). This is especially useful on large machines. Parker safety exhaust valves need a minimum 30 psi at P1.DCS-Parker-3.jpg

 Each safety valve requires a minimum input pressure of 30 psig

Follow the Standards which provide greater detail to the height of machine guards and the basic safe distances required for parts of the body. Further, stop-time measurement devices are to be used to measure the time it takes a machine to stop after a signal is given. Only then can the safeguarding device’s location

(ie light curtain) be established in relation to the hazard with the safety distance in consideration. Calculating where to put safety input devices like gates or light curtain is a critical step in machine design. Determine machine guard spacing prior to building and testing the machine. It’s also important to check the stop-

time device as part of your plant maintenance routine to ensure the machines stopping ability has not been compromised by wear or tampering.

Visit Parker Hannafin

Changing Scene

  • Prev
Reserve your spot now for Facing a World of Water Under Pressure       ...
Beckhoff Automation has announced a new machine learning (ML) solution that is seamlessly ...
“HANNOVER MESSE 2019 showed that it is the world’s most important platform for all ...
JMP Solutions, industrial technology partner to the Fortune 1000, has announced they achieved the ...
GE Healthcare and Rockwell Automation are combining their automation, IT and single-use solution ...

Parker whitepaper 400Innovative machine design is integral to the success of any machine builder. Smart machine design serves innovators with the reward of optimized space on the plant floor, considerable savings on components and installation, inherent safety by design and oh yes, it must meet the functional needs of the ever changing application. One machine will have multiple different speed and load requirements. A sound understanding of the components used in machine design is fundamental, knowledge of current machinery safety standards as well as an understanding in the desired outcome of the machines function. Read More

 

 

Peers & Profiles

  • Prev
After attending Georgian College in Barrie, Ontario for Electrical Engineering Technology and ...
At 68-years young, David is a veteran of the industry, spending the majority of his 40-year career ...
In 2015, Vector Drive Systems (Port Coquitlam, BC) and Advanced Drive Systems (Maple Ridge, BC), ...
JMP Solutions is a leader in industrial automation and technology, headquartered in London, ...
Bill Maki is a 51-year-old Electrical Engineer from Thunder Bay, Ontario working as a Control ...
Every story has a beginning.  Welcome to the world of innovations and progress. Over 90 years ...
In a recent sit-down Drives & Controls Solutions was able to learn a little about ...
Recently Panel Builder & Systems Integrator was invited to Rittal Canada’s Head ...
As our population grows and consumers continue to rely on technology for both essentials and ...
Few industrial innovations have weathered the years as well as heavy duty connectors. What was ...

Product News

  • Prev
Available immediately, the FE060-25-EM is the first servo drive of the new FlexPro digital drive ...
HARTING, HIROSE and FLUKE networks announced the availability of an adapter supporting the ix ...
SICK is launching its newest safety laser scanner, outdoorScan3. It is the first safety laser ...
New NFPA 79 requirements reinforce the need for thermoset insulated conductors, which Service ...
Looking for a smart and efficient alternative to dynamic braking? Look no further. The R1000 ...
FLIR Systems, Inc.introduces FLIR Thermal Studio, a thermal image analysis and reporting software ...
Single Phase Power Solutions introduces the 1-to-3 Power Source features a BELLE Motor which uses ...
Emerson is now offering professionals four new models of Greenlee battery hydraulic crimpers and ...
VMX Series Low Voltage Soft Starters; The control and protection you expect in an innovative soft ...
Sensors with 1 and 2 axes and 6 degrees of freedom provide fast response times and high signal ...

Rittal & EPLAN Pump out a Powerful Solution for Metro Vancouver

Kerrwil Publications

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2019 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil